SDMC TMP-3T Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Oprogramowanie SDMC TMP-3T. SDMC TMP-3T Product data Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 436
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
ibm.com/redbooks
IBM Systems Director
Management Console
Introduction and Overview
Thomas Libor, PhD
Allen Oh
Lakshmikanthan Selvarajan
Peter Wuestefeld
Documents the SDMC appliance, which
uses the Systems Director user interface
Discusses the differences
between the HMC and SDMC
Provides a practical guide to
the SDMC
Front cover
Przeglądanie stron 0
1 2 3 4 5 6 ... 435 436

Podsumowanie treści

Strona 1 - Management Console

ibm.com/redbooksIBM Systems Director Management ConsoleIntroduction and OverviewThomas Libor, PhDAllen OhLakshmikanthan SelvarajanPeter WuestefeldDocu

Strona 2

viii IBM Systems Director Management Console: Introduction and Overview14.5.2 Support Files Management . . . . . . . . . . . . . . . . . . . . . . .

Strona 3 - April 2011

74 IBM Systems Director Management Console: Introduction and OverviewFor the second method, perform the following steps to perform a transition of th

Strona 4

© Copyright IBM Corp. 2011. All rights reserved. 75Chapter 5. System managementThis chapter contains information about how to discover managed systems

Strona 5

76 IBM Systems Director Management Console: Introduction and Overview5.1 System discoveryDiscovery is the process by which IBM Systems Director iden

Strona 6

Chapter 5. System management 77You can launch the System Discovery tool by selecting the Common Tasks menu in the Welcome page or by clicking the Sy

Strona 7

78 IBM Systems Director Management Console: Introduction and OverviewVerify Connection pageThe Verify Connection page validates the connection betwee

Strona 8

Chapter 5. System management 79Request Access pageUse the Request Access page to request access to a system to which your SDMC has not yet authentic

Strona 9

80 IBM Systems Director Management Console: Introduction and OverviewConfigure Access pageUse the Configure Access page to view the status of Remote

Strona 10

Chapter 5. System management 815.1.2 Discovery of POWER processor-based bladesA POWER processor-based blade can be managed in very much the same wa

Strona 11

82 IBM Systems Director Management Console: Introduction and OverviewThe blade servers discovered directly and the blade servers that are discovered

Strona 12

Chapter 5. System management 83The DHCP service starts after the SDMC installation is completed. You can also manually start or stop the DHCP servic

Strona 13 - Figures xi

© Copyright IBM Corp. 2011. All rights reserved. ixFigures1-1 HMC and IVM management of POWER servers . . . . . . . . . . . . . . . . . . . . 21-2

Strona 14

84 IBM Systems Director Management Console: Introduction and Overview5.2 System discovery using the HMCYou can also discover and manage systems that

Strona 15 - Figures xiii

Chapter 5. System management 85The context menu is shown in Figure 5-4.Figure 5-4 Extended managementSDMC does not directly manage the systems con

Strona 16

86 IBM Systems Director Management Console: Introduction and OverviewIf you want to list the systems on the SDMC that are being directly managed, use

Strona 17

Chapter 5. System management 87Figure 5-5 Edit Host page5.3.2 Operations pageThe Operations page includes the tasks for server operations. Right-

Strona 18

88 IBM Systems Director Management Console: Introduction and OverviewThe tasks are available based on the current operating state of the managed syst

Strona 19 - Examples

Chapter 5. System management 895.3.6 Release Management pageThe Release Management page includes tasks for updating the firmware level of the manag

Strona 20

90 IBM Systems Director Management Console: Introduction and OverviewThe tasks are explained in detail in Chapter 14, “Service and support” on page 3

Strona 21

Chapter 5. System management 915.4 Hierarchical managementHierarchical management is a feature available in IBM Systems Director that enables you t

Strona 22 - Trademarks

92 IBM Systems Director Management Console: Introduction and Overview5.4.1 Enabling hierarchical managementTo enable hierarchical management on the

Strona 23

Chapter 5. System management 933. Discover the domain server (another SDMC that is connected to managed systems) from the System Discovery page. The

Strona 24 - The team who wrote this book

x IBM Systems Director Management Console: Introduction and Overview6-1 Available Power Units . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 25 - Comments welcome

94 IBM Systems Director Management Console: Introduction and Overview5.5 Capacity on DemandCapacity on Demand (CoD) offerings allow you to dynamical

Strona 26

Chapter 5. System management 95Right-click the managed system and select System Configuration  Capacity on Demand (CoD) to launch the CoD page. The

Strona 27 - Overview

96 IBM Systems Director Management Console: Introduction and OverviewProcessor Settings and Memory Settings are hyperlinks and clicking any of them t

Strona 28 - Private Mgmt Network II

Chapter 5. System management 975.5.4 CoD operationsYou can perform all CoD related operations from the CoD page. These operations are exactly the s

Strona 29 - Console

98 IBM Systems Director Management Console: Introduction and Overview

Strona 30 - Management

© Copyright IBM Corp. 2011. All rights reserved. 99Chapter 6. Power Unit managementThis chapter describes how the IBM Systems Director Management Cons

Strona 31 - Chapter 1. Overview 5

100 IBM Systems Director Management Console: Introduction and Overview6.1 Power Unit managmentWhen a host is discovered, so are the Power Units. The

Strona 32

Chapter 6. Power Unit management 1016.1.1 Edit Power Unit pageYou can view and edit the properties of a Power Unit using the Edit Power Unit page.

Strona 33 - Chapter 1. Overview 7

102 IBM Systems Director Management Console: Introduction and Overview6.1.2 Bulk Power Assembly (BPA) Status pageYou can view the state of the conne

Strona 34

Chapter 6. Power Unit management 103You have to enter the current password, then a new password, and verify it by entering it again.If you change th

Strona 35

Figures xi8-17 Create Virtual Server: Optical device and media selection . . . . . . . . . . 1498-18 Create Virtual Server: Load Source and Consol

Strona 36 - 1.6 Functional differences

104 IBM Systems Director Management Console: Introduction and Overview6.1.5 Launch Advanced System Management pageYou can open the Advanced System M

Strona 37 - 1.6.2 Users and roles

Chapter 6. Power Unit management 105Rebuilding, or recreating, the managed frame acts much like a refresh of the frame information. Rebuilding a fra

Strona 38 - 1.6.6 Backup and restore

106 IBM Systems Director Management Console: Introduction and Overview

Strona 39 - 1.6.7 SDMC considerations

© Copyright IBM Corp. 2011. All rights reserved. 107Chapter 7. Firmware updatesThis chapter cover installing and managing firmware on Power Systems fr

Strona 40

108 IBM Systems Director Management Console: Introduction and Overview7.1 Update ManagerThe Update Manager is the component of SDMC used to perform

Strona 41 - Installation

Chapter 7. Firmware updates 109Chapter 10, “Update Manager”, in Implementing IBM Systems Director 6.1, SG24-7694.In this chapter, we focus on only t

Strona 42 - 2.1 Prerequisites

110 IBM Systems Director Management Console: Introduction and Overview7.1.1 Readiness Check pageBefore performing any of the installation or managem

Strona 43 -

Chapter 7. Firmware updates 111Click the Gather Target Information button on the Readiness Check page to run the Readiness Check on the target syste

Strona 44

112 IBM Systems Director Management Console: Introduction and OverviewIf the selected system pass the Readiness Check, the Readiness column shows as

Strona 45

Chapter 7. Firmware updates 113򐂰 SDMC requires more update files for an image than just the .xml and .rpm files; it also requires the .dd.xml, .pd.s

Strona 46

xii IBM Systems Director Management Console: Introduction and Overview8-60 Select Validate from the partition page . . . . . . . . . . . . . . . . .

Strona 47

114 IBM Systems Director Management Console: Introduction and OverviewGetting updatesThe easiest way to check for and download the latest updates is

Strona 48

Chapter 7. Firmware updates 115The user can then select the type of updates to check for on the Check for Updates page (Figure 7-7) and continue thr

Strona 49

116 IBM Systems Director Management Console: Introduction and OverviewThe updates for any IBM hardware managed by the SDMC (including Power Systems a

Strona 50

Chapter 7. Firmware updates 117If the USB is formatted for a vFAT file system, run the following command:mount -t vfat /dev/sda1 /mnt/usbThe simples

Strona 51

118 IBM Systems Director Management Console: Introduction and OverviewIn the same Common tasks section, there is also a link for Import Updates by FT

Strona 52

Chapter 7. Firmware updates 119Updating target systemsOn the Update Manager page, you can start an installation from the Show needed updates, Show a

Strona 53

120 IBM Systems Director Management Console: Introduction and OverviewTo update the target systems, perform the following steps:1. To install the lat

Strona 54

Chapter 7. Firmware updates 1212. The Show Needed Updates page opens and show the system(s) from the selected list. Click the Show Needed Updates bu

Strona 55

122 IBM Systems Director Management Console: Introduction and OverviewAlso note the error message that appears at the top of the page stating that an

Strona 56

Chapter 7. Firmware updates 1234. On the Systems page that opens (Figure 7-14), select the target system to which you want to apply the previously s

Strona 57

Figures xiii9-42 Snapshot manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2619-43 View Trace Logs . . . .

Strona 58

124 IBM Systems Director Management Console: Introduction and Overview5. The Options page shows any applicable installation options or any additional

Strona 59

Chapter 7. Firmware updates 1256. From the Start Target Checks page, initiate readiness and concurrency checks for the selected targets. These check

Strona 60

126 IBM Systems Director Management Console: Introduction and Overview7.1.3 Power Firmware Management tasksYou can manage firmware on Power Systems

Strona 61

Chapter 7. Firmware updates 127Procedures for Power Firmware Management operationsFrom the Resources tab on the Welcome page on the SDMC GUI, perfor

Strona 62

128 IBM Systems Director Management Console: Introduction and OverviewThe Power Firmware Management page opens (Figure 7-18). As with the readiness c

Strona 63

Chapter 7. Firmware updates 1292. After the target information is gathered, the Accept/Reject, Disruptive Activate, Synchronize, Remove and Activate

Strona 64

130 IBM Systems Director Management Console: Introduction and Overview3. Click the Start Accept Task button (Figure 7-20).Figure 7-20 Start Accept

Strona 65

© Copyright IBM Corp. 2011. All rights reserved. 131Chapter 8. Virtual Server operationThe Virtual Server operation contains the operations for Virtua

Strona 66

132 IBM Systems Director Management Console: Introduction and Overview8.1 Virtual Server creationOn the Hardware Management Console, Virtual Servers

Strona 67

Chapter 8. Virtual Server operation 133To create a Virtual Server, perform the following steps:1. From the Welcome page, locate the host on which th

Strona 68

xiv IBM Systems Director Management Console: Introduction and Overview14-14 Manage Support Files system wide view . . . . . . . . . . . . . . . . .

Strona 69

134 IBM Systems Director Management Console: Introduction and OverviewFigure 8-2 shows the wizard that allows you to create a Virtual Server.2. On th

Strona 70

Chapter 8. Virtual Server operation 1353. When you are creating a Virtual Server for the Virtual I/O Server environment type, some selections will b

Strona 71

136 IBM Systems Director Management Console: Introduction and Overview4. To create IBM i Virtual Servers, use the Memory menu (Figure 8-4). The diffe

Strona 72

Chapter 8. Virtual Server operation 1375. The assigned memory can be dedicated or shared (Figure 8-5). The Shared option needs the Active Memory Sha

Strona 73

138 IBM Systems Director Management Console: Introduction and Overview6. As shown in Figure 8-6, the default processor mode for Virtual Servers is Sh

Strona 74

Chapter 8. Virtual Server operation 1397. As shown in Figure 8-7, the wizard queries the available Ethernet connections of the Virtual I/O Servers.

Strona 75

140 IBM Systems Director Management Console: Introduction and OverviewIf you would like to add a Logical Host Ethernet Adapter port to the partition,

Strona 76

Chapter 8. Virtual Server operation 141The ability to add storage adapters automatically when creating a Virtual Server was added to provide legacy

Strona 77

142 IBM Systems Director Management Console: Introduction and OverviewFigure 8-10 Create Virtual Server: Assign storage adapter IDs

Strona 78

Chapter 8. Virtual Server operation 14310.The results are shown in Figure 8-11. If you decide to add another adapter to a second Virtual I/O Server,

Strona 79

© Copyright IBM Corp. 2011. All rights reserved. xvTables1-1 Server firmware support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 80

144 IBM Systems Director Management Console: Introduction and Overview11.If automatic storage adapter creation is chosen (Figure 8-12), additional ch

Strona 81

Chapter 8. Virtual Server operation 14512.Click Next. The page shown in Figure 8-13 opens. Clicking the Create Virtual Disk button opens a page wher

Strona 82

146 IBM Systems Director Management Console: Introduction and OverviewAs shown in Figure 8-14, the Virtual I/O Server, the name, the disk pool and th

Strona 83

Chapter 8. Virtual Server operation 14713.If automatic storage adapter creation for Physical Disks was checked, you can select available disks in al

Strona 84

148 IBM Systems Director Management Console: Introduction and Overview14.If you select Fibre Channel in the page shown in Figure 8-16, then, on the S

Strona 85

Chapter 8. Virtual Server operation 14915.In Figure 8-17, you can select either physical or virtual optical media. A virtual optical device is chose

Strona 86

150 IBM Systems Director Management Console: Introduction and Overview16.If you created an IBM i Virtual Server, an additional page is available befo

Strona 87

Chapter 8. Virtual Server operation 15117.The last page in the Create Virtual Server Wizard, the Physical I/O Adapters page, allows you to attach ph

Strona 88

152 IBM Systems Director Management Console: Introduction and OverviewExample 8-1 is a sample command that is used to create an Virtual Server.Exampl

Strona 89

Chapter 8. Virtual Server operation 153To activate a Virtual Server, perform the following steps:1. Right-click the server name and select Operation

Strona 90

xvi IBM Systems Director Management Console: Introduction and OverviewA-19 listjobs command . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 91

154 IBM Systems Director Management Console: Introduction and Overview2. Select a profile. In our example, we only have the default profile, which is

Strona 92

Chapter 8. Virtual Server operation 1553. Click the Advanced tab and select the options for the keylock position and boot mode (Figure 8-22).Figure

Strona 93

156 IBM Systems Director Management Console: Introduction and Overview4. The Welcome page opens and shows the state and detailed state of the Virtual

Strona 94

Chapter 8. Virtual Server operation 1578.3 Virtual Server shutdownTo shut down a Virtual Server, navigate to the Welcome page, right-click the name

Strona 95

158 IBM Systems Director Management Console: Introduction and OverviewThe next page (Figure 8-25) shows the available options for shutting down the o

Strona 96

Chapter 8. Virtual Server operation 1598.4 Virtual Server managementThe Manage Virtual Server menu option in the Welcome page allows you to customi

Strona 97

160 IBM Systems Director Management Console: Introduction and OverviewTo manage the Virtual Server, navigate to the Welcome page, right-click the nam

Strona 98

Chapter 8. Virtual Server operation 161The page with the General Settings tab opens (Figure 8-27). The settings that can be changed here are shown i

Strona 99

162 IBM Systems Director Management Console: Introduction and OverviewThe Tasks button (Figure 8-28) allows you to execute the following tasks direct

Strona 100

Chapter 8. Virtual Server operation 163The Processor page allows you to change the processor related settings of the Virtual Server, including the p

Strona 101 - System management

© Copyright IBM Corp. 2011. All rights reserved. xviiExamples2-1 OVF Tool CLI using an OVA file on Windows. . . . . . . . . . . . . . . . . . . . . .

Strona 102 - 5.1 System discovery

164 IBM Systems Director Management Console: Introduction and OverviewNote the blue values in the drop-down menu and the changed appearance of the bu

Strona 103

Chapter 8. Virtual Server operation 165The default memory mode for Virtual Servers is Dedicated and Active Memory Expansion (AME) is enabled by defa

Strona 104 - Verify Connection page

166 IBM Systems Director Management Console: Introduction and OverviewIf the memory mode is set to Shared, as shown in Figure 8-32, Advanced Memory S

Strona 105 - Request Access page

Chapter 8. Virtual Server operation 167On the following Network tab (Figure 8-33), you can configure virtual network adapters for the Virtual Server

Strona 106 - Revoke Access page

168 IBM Systems Director Management Console: Introduction and OverviewIf the check box right to the virtual network adapter is checked, the Edit butt

Strona 107

Chapter 8. Virtual Server operation 169On the Storage Adapters page (Figure 8-35), you can removed existing storage adapters if you check the check

Strona 108 - 5.1.4 Auto discovery

170 IBM Systems Director Management Console: Introduction and OverviewTo add an storage adapter, click the Add button (Figure 8-35 on page 169) and e

Strona 109 - 5.1.5 IP address rules

Chapter 8. Virtual Server operation 171If you chose to add a Virtual Fibre Channel adapter, the page shown in Figure 8-37 opens. Note that the World

Strona 110

172 IBM Systems Director Management Console: Introduction and OverviewOn the Storage Devices page (Figure 8-38), three types of storage devices can b

Strona 111

Chapter 8. Virtual Server operation 173Figure 8-39 shows the available physical volumes on the Virtual I/O servers. We select hdisk8 on the second V

Strona 113 - 5.3.2 Operations page

xviii IBM Systems Director Management Console: Introduction and Overview

Strona 114 - 5.3.5 Hardware page

174 IBM Systems Director Management Console: Introduction and OverviewThe Add Fibre Channel menu allows you to add additional Virtual Fibre Channel a

Strona 115

Chapter 8. Virtual Server operation 175The Media Devices page lets you add media devices to the Virtual Server, that is optical devices, such as CD

Strona 116

176 IBM Systems Director Management Console: Introduction and OverviewFigure 8-42 shows the available Physical Media devices. Click the OK button to

Strona 117 - 5.4 Hierarchical management

Chapter 8. Virtual Server operation 177Clicking Add in the Virtual Media section of the Media Devices page opens a list of the available virtual med

Strona 118

178 IBM Systems Director Management Console: Introduction and OverviewThe task in Figure 8-43 on page 177 creates a Virtual Optical device adapter th

Strona 119

Chapter 8. Virtual Server operation 179The last page in Manage Virtual Servers (Figure 8-45) allows you to add physical adapters to the Virtual Serv

Strona 120 - 5.5 Capacity on Demand

180 IBM Systems Director Management Console: Introduction and OverviewIf you click the Add button, the list of physical adapters on the server appear

Strona 121 - 5.5.2 Capacity on Demand

Chapter 8. Virtual Server operation 181When adding the physical adapters and virtual adapters, there is a short period of time where the addition of

Strona 122 - 5.5.3 Advanced Functions

182 IBM Systems Director Management Console: Introduction and Overview8.4.1 Command-line usageChanges to the Virtual Server configuration also can b

Strona 123 - 5.5.4 CoD operations

Chapter 8. Virtual Server operation 183On the Welcome page, navigate to the Virtual Server and right-click the Virtual Server to access the menu opt

Strona 124

© Copyright IBM Corp. 2011. All rights reserved. xixNoticesThis information was developed for products and services offered in the U.S.A. IBM may not

Strona 125 - Power Unit management

184 IBM Systems Director Management Console: Introduction and OverviewClicking Save Current Configuration takes you to the Save page (Figure 8-49). H

Strona 126 - 6.1 Power Unit managment

Chapter 8. Virtual Server operation 1858.4.3 Virtual Server ProfilesThe Virtual Server Profile contains the configuration of the Virtual Server. Wh

Strona 127 - 6.1.1 Edit Power Unit page

186 IBM Systems Director Management Console: Introduction and OverviewRemember that the display of menus is context sensitive and shows only tasks an

Strona 128 - 6.1.3 Change Password page

Chapter 8. Virtual Server operation 187To access the profiles of a Virtual Server, refer to Figure 8-48 on page 183. Select System Configuration  M

Strona 129 - 6.1.4 Initialize Frame page

188 IBM Systems Director Management Console: Introduction and OverviewClick Edit to open the Logical Partition Profile Properties menu. This menu all

Strona 130 - 6.1.7 Rebuild page

Chapter 8. Virtual Server operation 189There are initially no System Profiles defined for a server. To create a System Profile, enter a name into th

Strona 131

190 IBM Systems Director Management Console: Introduction and OverviewExpand the toggle of the Virtual Server to see all the profiles of that Virtual

Strona 132

Chapter 8. Virtual Server operation 191Note that Virtual Servers using shared memory cannot be added to a system profile. If you attempt to add thes

Strona 133 - Firmware updates

192 IBM Systems Director Management Console: Introduction and OverviewCommand-line usageA System Profile can also be defined by running smcli mksyscf

Strona 134 - 7.1 Update Manager

Chapter 8. Virtual Server operation 1938.5.1 Suspend a Virtual ServerTo perform a suspend operation on an Virtual Server, perform the following ste

Strona 135

xx IBM Systems Director Management Console: Introduction and OverviewTrademarksIBM, the IBM logo, and ibm.com are trademarks or registered trademarks

Strona 136 - 7.1.1 Readiness Check page

194 IBM Systems Director Management Console: Introduction and Overview2. From the Partition Suspend/Resume page (Figure 8-59), you can select Suspend

Strona 137

Chapter 8. Virtual Server operation 195The Resume status page shows the progress of the resume operation and shows a success completion.8.6 Mobilit

Strona 138 - 7.1.2 Installing updates

196 IBM Systems Director Management Console: Introduction and Overview2. In the Validate page, the Migrate and View VLAN buttons should be currently

Strona 139

© Copyright IBM Corp. 2011. All rights reserved. 197Chapter 9. IBM Systems Director Management Console managementThis chapter covers the various tasks

Strona 140 - Getting updates

198 IBM Systems Director Management Console: Introduction and Overview9.1 User management and securityVirtualization means that more than one system

Strona 141

Chapter 9. IBM Systems Director Management Console management 199Because the terminology and the structure of user and security management changes f

Strona 142

200 IBM Systems Director Management Console: Introduction and Overview9.1.2 IBM Systems Director conceptsUsers in IBM Systems Director are users tha

Strona 143

Chapter 9. IBM Systems Director Management Console management 201򐂰 sysadminThis is the user designed to be the primary administrator of the SDMC.򐂰 p

Strona 144

202 IBM Systems Director Management Console: Introduction and OverviewUser groupsThe following user registry groups are employed for granting granula

Strona 145 - Updating target systems

Chapter 9. IBM Systems Director Management Console management 203Refer to Figure 9-1 for a display of users and their initially assigned groups afte

Strona 146

© Copyright IBM Corp. 2011. All rights reserved. xxiPrefaceThis IBM® Redbooks® publication positions the IBM Systems Director Management Console (SDMC

Strona 147

204 IBM Systems Director Management Console: Introduction and Overview AssignedRoles: {'SMAdministrator' applied to <ALL GROUPS>}

Strona 148

Chapter 9. IBM Systems Director Management Console management 205RolesThere are four roles that are initially defined on the SDMC:򐂰 SMAdministratorT

Strona 149

206 IBM Systems Director Management Console: Introduction and OverviewCreating a roleTo create a role, perform the following steps:1. Expand Security

Strona 150

Chapter 9. IBM Systems Director Management Console management 2072. Click Create to open the Roles wizard Welcome page. Clicking Next opens the Name

Strona 151

208 IBM Systems Director Management Console: Introduction and Overview3. Clicking Next opens the Permissions page (Figure 9-4). You see a page with t

Strona 152

Chapter 9. IBM Systems Director Management Console management 2094. Click the plus sign next to any role to expand it. All permissions collected in

Strona 153

210 IBM Systems Director Management Console: Introduction and OverviewListing rolesRoles can be listed using the command line by running smcli lsrole

Strona 154

Chapter 9. IBM Systems Director Management Console management 211GroupsThe concept of groups in the SDMC is equivalent to that of Resource Roles in

Strona 155 - Figure 7-19 Accept

212 IBM Systems Director Management Console: Introduction and OverviewCreating a groupTo create a group, perform the following steps:1. Click Navigat

Strona 156

Chapter 9. IBM Systems Director Management Console management 2132. Click Create Group to open the Welcome page of the Group Editor wizard (Figure 9

Strona 157 - Virtual Server operation

xxii IBM Systems Director Management Console: Introduction and OverviewThe team who wrote this bookThis book was produced by a team of specialists fr

Strona 158 - 8.1 Virtual Server creation

214 IBM Systems Director Management Console: Introduction and Overview3. Enter a name for the group and, optionally, a description on the Name page a

Strona 159

Chapter 9. IBM Systems Director Management Console management 2154. Click Next to open the Define page, which allows for a wide selection of resourc

Strona 160

216 IBM Systems Director Management Console: Introduction and Overview5. To select a single entry, for example, a Virtual Server, click All Systems.

Strona 161

Chapter 9. IBM Systems Director Management Console management 2176. Click Next, and the Summary page that lists the resources assigned to this group

Strona 162 - Source/Console pane

218 IBM Systems Director Management Console: Introduction and OverviewAfter clicking Finish, the wizard closes and the new group is shown on the Grou

Strona 163

Chapter 9. IBM Systems Director Management Console management 219To assign a role to a user, perform the following steps:1. In the left pane of the

Strona 164

220 IBM Systems Director Management Console: Introduction and Overview2. The Welcome page of the Assign Role wizard opens. Click Next to open the Rol

Strona 165

Chapter 9. IBM Systems Director Management Console management 2213. Select the roles you want to assign to this user and click Next to open the Grou

Strona 166

222 IBM Systems Director Management Console: Introduction and Overview4. Click Next to open the Summary page, which lists permissions and groups assi

Strona 167

Chapter 9. IBM Systems Director Management Console management 223Authentication methodsThree different authentication methods can be used with SDMC.

Strona 168

Preface xxiiiUdo SachsSVA GermanyNow you can become a published author, too!Here's an opportunity to spotlight your skills, grow your career, a

Strona 169

224 IBM Systems Director Management Console: Introduction and OverviewLocal authenticationTo perform local authentication, perform the following step

Strona 170

Chapter 9. IBM Systems Director Management Console management 2252. A page opens where the user credentials can be specified. Refer to Figure 9-19 f

Strona 171

226 IBM Systems Director Management Console: Introduction and OverviewOptionally, you can specify a user description (Description), an SSH session ti

Strona 172

Chapter 9. IBM Systems Director Management Console management 227򐂰 Users need only one user ID and password, as opposed to multiple accounts for eac

Strona 173

228 IBM Systems Director Management Console: Introduction and Overview --bindpw password --loginattr uid --groupfilter '(|(objectclass=g

Strona 174

Chapter 9. IBM Systems Director Management Console management 229Another method to configure SDMC for LDAP user management is by using a GUI. In the

Strona 175

230 IBM Systems Director Management Console: Introduction and OverviewThe Welcome page of the LDAP client configuration wizard is shown in Figure 9-2

Strona 176

Chapter 9. IBM Systems Director Management Console management 231Figure 9-22 shows how to create a user for LDAP authentication. No other informatio

Strona 177 - Command-line usage

232 IBM Systems Director Management Console: Introduction and OverviewKerberosSDMC allows for Kerberos authentication. A detailed configuration walkt

Strona 178

Chapter 9. IBM Systems Director Management Console management 233SDMC can be configured as a Kerberos client in the GUI by clicking the Configure Ke

Strona 179

xxiv IBM Systems Director Management Console: Introduction and OverviewStay connected to IBM Redbooks򐂰 Find us on Facebook:http://www.facebook.com/IB

Strona 180

234 IBM Systems Director Management Console: Introduction and OverviewAfter clicking the link, a wizard walks you through the required steps to compl

Strona 181

Chapter 9. IBM Systems Director Management Console management 235After configuring the Kerberos client, a user can be added to the SDMC by clicking

Strona 182

236 IBM Systems Director Management Console: Introduction and OverviewExample 9-12 provides an example about how to use the mkuser command with Kerbe

Strona 183 - 8.3 Virtual Server shutdown

Chapter 9. IBM Systems Director Management Console management 237Modifying user propertiesAfter the new user account has been created, its propertie

Strona 184

238 IBM Systems Director Management Console: Introduction and OverviewClick the newly created user to open the User properties page (Figure 9-27). In

Strona 185

Chapter 9. IBM Systems Director Management Console management 239All of the listed attributes can be changed except the first two, which were define

Strona 186 - Virtual Server (Figure 8-26)

240 IBM Systems Director Management Console: Introduction and OverviewDeleting usersTo remove a user using the command line, run smcli rmuser (Exampl

Strona 187

Chapter 9. IBM Systems Director Management Console management 241To take advantage of the additional security and ease of setup, implement service n

Strona 188

242 IBM Systems Director Management Console: Introduction and OverviewTo view and change the network settings go to the Settings tab on the Welcome p

Strona 189

Chapter 9. IBM Systems Director Management Console management 243When you select it, the network configuration wizard starts (Figure 9-30).Figure 9-

Strona 190

© Copyright IBM Corp. 2011. All rights reserved. 1Chapter 1. OverviewThe IBM Systems Director Management Console (SDMC) is the successor to the Hardwa

Strona 191

244 IBM Systems Director Management Console: Introduction and OverviewDHCPIf you select Configure System as a DHCP server, you get a page where you c

Strona 192

Chapter 9. IBM Systems Director Management Console management 245IP addressIf you select Standard network interface, you get a page where you can se

Strona 193

246 IBM Systems Director Management Console: Introduction and OverviewFirewallAfter selecting a DHCP or static IP address, the Firewall menu opens, w

Strona 194

Chapter 9. IBM Systems Director Management Console management 247IBM Systems Director Console HTTP Access8421:TCP NoCommon Agent Service(CAS) 9510:T

Strona 195

248 IBM Systems Director Management Console: Introduction and OverviewAfter configuring the firewall, the LAN adapter page opens again, where you can

Strona 196 - Figure 8-36

Chapter 9. IBM Systems Director Management Console management 249DNSIn the next page, you can specify one or more Domain Name Services (DNS) server

Strona 197

250 IBM Systems Director Management Console: Introduction and OverviewNetwork reconfigurationIn the next page, a job is scheduled for the reconfigura

Strona 198

Chapter 9. IBM Systems Director Management Console management 251You can close this page by clicking close. You can see the status of the job by sel

Strona 199

252 IBM Systems Director Management Console: Introduction and Overview9.2.2 Configuring network settings using the SDMC CLIYou can also view and cha

Strona 200

Chapter 9. IBM Systems Director Management Console management 2539.2.3 Testing network connectivityThe network connectivity can only be tested by u

Strona 201

2 IBM Systems Director Management Console: Introduction and Overview1.1 Power Systems management consolesThe Hardware Management Console (HMC) allow

Strona 202

254 IBM Systems Director Management Console: Introduction and OverviewBackupTo perform the backup, perform the following steps:1. Check if the system

Strona 203 - (Figure 8-43)

Chapter 9. IBM Systems Director Management Console management 255Here is our example of this command:backup -l usb -Y6. The backup command starts th

Strona 204

256 IBM Systems Director Management Console: Introduction and Overview-l The location to store the backup file. If sftp is specified, the -s argumen

Strona 205

Chapter 9. IBM Systems Director Management Console management 2572. Select the virtual machine which want to back up, right-click it, and select Sna

Strona 206

258 IBM Systems Director Management Console: Introduction and Overview3. Enter the snapshot name and description, and create a new snapshot of the se

Strona 207

Chapter 9. IBM Systems Director Management Console management 2594. The snapshot is stored on the host. To copy it to another reliable location, sel

Strona 208 - 8.4.2 Current Configuration

260 IBM Systems Director Management Console: Introduction and OverviewSteps for restore using the VMware vSphere ClientTo perform a restore using the

Strona 209 - (Figure 8-48)

Chapter 9. IBM Systems Director Management Console management 2613. You can also select to restore from other snapshots by selecting the Snapshot Ma

Strona 210

262 IBM Systems Director Management Console: Introduction and OverviewKVM backup procedureThe SDMC software appliance back up on KVM requires LVM sup

Strona 211

Chapter 9. IBM Systems Director Management Console management 26311.Create the SDMC /Snapshot_LV_Dir/sdmc/data/images directory by running the follo

Strona 212

Chapter 1. Overview 3The characteristics of those management consoles are as follows:򐂰 Hardware Management Console:– Is implemented as an external,

Strona 213

264 IBM Systems Director Management Console: Introduction and Overviewlsrm -rf *4. Extract the tarball to the images directory and time it by running

Strona 214 - 8.4.4 Server Profiles

Chapter 9. IBM Systems Director Management Console management 265/var/hsc/log/iqzdtrac.trm This log files contains information related to Common Con

Strona 215

266 IBM Systems Director Management Console: Introduction and OverviewTrace logs in GUIYou can view the trace logs of the SDMC using the graphical us

Strona 216

Chapter 9. IBM Systems Director Management Console management 2679.4.2 IBM Systems Director logsThe log files related to IBM Systems Director are l

Strona 217

268 IBM Systems Director Management Console: Introduction and OverviewSDMC allows you to configure the settings for the trace and error logs. This ta

Strona 218 - 8.5 Suspend and resume

Chapter 9. IBM Systems Director Management Console management 269Here are the available trace levels:򐂰 Severe򐂰 Warning򐂰 Info򐂰 Fine򐂰 Finer򐂰 FinestBy

Strona 219 - (Figure 8-58)

270 IBM Systems Director Management Console: Introduction and OverviewThe usage of the pedbg command is as follows:pedbg [ -d [on | off] | -c | [-c &

Strona 220

Chapter 9. IBM Systems Director Management Console management 271Run the lsconfig -v command to obtain the UVMID:sysadmin@dd174:~> lsconfig -vvpd

Strona 221 - 8.6 Mobility

272 IBM Systems Director Management Console: Introduction and OverviewThere are three types of SDMC appliance updates:򐂰 Service pack updates򐂰 Interim

Strona 222 - Figure 8-61 Click Validate

Chapter 9. IBM Systems Director Management Console management 273To auto-check and download applicable updates (which is easiest if the SDMC has acc

Strona 223

IBM Systems Director Management Console: Introduction and OverviewApril 2011International Technical Support OrganizationSG24-7860-00

Strona 224

4 IBM Systems Director Management Console: Introduction and OverviewSee Figure 1-2 for an overview of how the SDMC is placed in an enterprise-wide ad

Strona 225 - HMC tasks

274 IBM Systems Director Management Console: Introduction and OverviewIf the SDMC does not have access to the internet, the manual procedures for ins

Strona 226

© Copyright IBM Corp. 2011. All rights reserved. 275Chapter 10. Command-line interfaceThis chapter discusses the command-line interface (CLI) of the I

Strona 227

276 IBM Systems Director Management Console: Introduction and Overview10.1 SDMC command-line interfaceIn the SDMC CLI there are three types of comma

Strona 228 - User groups

Chapter 10. Command-line interface 277Table 10-1 provides a listing of the most important IBM Systems Director appliance commands and their usage. F

Strona 229

278 IBM Systems Director Management Console: Introduction and Overview10.1.2 IBM Systems Director application commandsThe IBM Systems Director appli

Strona 230

Chapter 10. Command-line interface 279Availability/mkvsmfarmAvailability/mkvsmmigratetaskLEDCLI/chledLEDCLI/lsledauditing/chauditauditing/lsauditAs

Strona 231

280 IBM Systems Director Management Console: Introduction and Overview10.1.3 Power Systems management commandsThe Power Systems management (psm) com

Strona 232 - Creating a role

Chapter 10. Command-line interface 281psm/chledpsm/chlparstatepsm/chlparutilpsm/chpwrmgmtpsm/chstatpsm/chsvcpsm/chsyscfgpsm/chsyspwdpsm/chsysstateps

Strona 233

282 IBM Systems Director Management Console: Introduction and OverviewThe output of the Power Systems management commands on the SDMC is the same as

Strona 234

Chapter 10. Command-line interface 283bkprofdata Backs up profile data for the managed system.The -o option will be ignored by SDMC.chcod Performs C

Strona 235

Chapter 1. Overview 5See Figure 1-3 for a schematic overview. This figure shows where the SDMC fits into the overall view of IBM Systems Director sy

Strona 236 - Deleting a role

284 IBM Systems Director Management Console: Introduction and Overviewcpdump Copies managed system dumps and managed frame dumps from the SDMC to DVD

Strona 237

Chapter 10. Command-line interface 285lslock Lists which SDMC owns the lock on the managed frame.No change.lslparmigr Lists partition migration info

Strona 238 - Creating a group

286 IBM Systems Director Management Console: Introduction and Overviewlsvet Lists Capacity on Demand advanced functions activation information for th

Strona 239 - (Figure 9-8)

Chapter 10. Command-line interface 28710.3 HMC commands not supported on the SDMCTable 10-4 lists the HMC commands listed that are no longer suppor

Strona 240

288 IBM Systems Director Management Console: Introduction and Overviewchaccfg smcli chrole. chhmc chnetcfg. chhmcencr No replacement available.chhmcf

Strona 241

© Copyright IBM Corp. 2011. All rights reserved. 289Chapter 11. Schedule operationsIn this chapter, we describe how to schedule operations for certain

Strona 242

290 IBM Systems Director Management Console: Introduction and Overview11.1 Scheduling operations for managed systems and Virtual ServersTo schedule

Strona 243

Chapter 11. Schedule operations 291򐂰 Power On򐂰 Manage Utility CoD򐂰 Modify Shared Processor Pool򐂰 Modify Virtual Server Pool Assignment򐂰 Modify Power

Strona 244 - Groups page (Figure 9-13)

292 IBM Systems Director Management Console: Introduction and OverviewClick OK, and the Task Launch Dialog page opens (Figure 11-3).Figure 11-3 Tas

Strona 245

Chapter 11. Schedule operations 293Monthly You can specify the duration of how long the job repeats, if the job should run on weekends, and on which

Strona 246 - Roles page (Figure 9-15)

6 IBM Systems Director Management Console: Introduction and Overview1.3 IVM, HMC, and SDMC supportThe transition will begin in the second half of 20

Strona 247

294 IBM Systems Director Management Console: Introduction and Overview11.1.4 Creating the jobWhen you have made your selections in the Task Launch D

Strona 248

Chapter 11. Schedule operations 295Figure 11-5 shows an overview over the scheduled, active, and completed jobs.Figure 11-5 Active and Schedule Jo

Strona 249 - 9.1.5 User management

296 IBM Systems Director Management Console: Introduction and OverviewIf you click a job, you can view the properties of the selected job (Figure 11-

Strona 250 - Local authentication

Chapter 11. Schedule operations 29711.3 Automation ManagerIf you select the Automation Manager on the main Manage tab, you get an overview over the

Strona 251

298 IBM Systems Director Management Console: Introduction and Overview

Strona 252

© Copyright IBM Corp. 2011. All rights reserved. 299Chapter 12. High availability and redundancyImplementing IBM Systems Director Management Console (

Strona 253

300 IBM Systems Director Management Console: Introduction and Overview12.1 Systems Director Management Console High Availability versus redundant se

Strona 254

Chapter 12. High availability and redundancy 301򐂰 For an environment where the SDMC is used for agent OS management and there is a high availability

Strona 255

302 IBM Systems Director Management Console: Introduction and OverviewFor this setup, configure an SDMC (A) to point to the active agent manager runn

Strona 256

Chapter 12. High availability and redundancy 303Figure 12-3 shows both the software and hardware stack that of an SDMC High Availability environment

Strona 257

Chapter 1. Overview 7This support plan is the same plan as the support plan for the Hardware Management Console. For proper and supported function,

Strona 258 - Kerberos

304 IBM Systems Director Management Console: Introduction and OverviewRunning the setup wizard or using CLI commands on the SDMC designated to be the

Strona 259

Chapter 12. High availability and redundancy 305Primary node This is the node you use to set up high availability. It is initially the active node.

Strona 260

306 IBM Systems Director Management Console: Introduction and Overview12.2.3 SDMC High Availability processes monitoredThese are the processes monit

Strona 261

Chapter 12. High availability and redundancy 30712.3 Active/Passive High Availability: Configuration planningYou need to plan the setup of SDMC Hig

Strona 262

308 IBM Systems Director Management Console: Introduction and Overview12.3.1 Network requirementsBecause data is continually replicated between the

Strona 263 - Modifying user properties

Chapter 12. High availability and redundancy 309Replication IP addressBecause the replication IP address on each of the two SDMC nodes in the High A

Strona 264

310 IBM Systems Director Management Console: Introduction and Overview򐂰 Choose an address that each node can reach by a single path. If there are mul

Strona 265

Chapter 12. High availability and redundancy 31112.3.2 DHCP considerationsThe SDMC cannot be a DHCP client. If your network is set up so that one D

Strona 266 - 9.2 Network configuration

312 IBM Systems Director Management Console: Introduction and OverviewShared DHCP configurationThe DHCP server is only run on the active node. Config

Strona 267

Chapter 12. High availability and redundancy 31312.4.1 Configuration using SDMC High Availability setup wizardPerform the following steps:1. Open u

Strona 268

8 IBM Systems Director Management Console: Introduction and OverviewThe virtualization layer for the hardware appliance is fixed and cannot be change

Strona 269 - LAN adapter

314 IBM Systems Director Management Console: Introduction and Overview2. The Welcome page for the High Availability setup wizard (Figure 12-8) shows

Strona 270 - Figure 9-31 DHCP server

Chapter 12. High availability and redundancy 3153. In the Secondary Node setup page (Figure 12-9), enter the IP address or host name and the passwor

Strona 271 - IP address

316 IBM Systems Director Management Console: Introduction and Overview5. In the Replication IP Address page (Figure 12-10), specify the IP addresses

Strona 272 - Firewall

Chapter 12. High availability and redundancy 3176. If you want a network status IP address, determine an appropriate IP address and enter it into th

Strona 273

318 IBM Systems Director Management Console: Introduction and Overview7. Determine the available IP address to be used as the floating IP address and

Strona 274 - Host and gateway

Chapter 12. High availability and redundancy 3198. If you use Systems Director Common Agent Services, you must specify an agent manager IP address s

Strona 275 - Figure 9-34 DNS menu

320 IBM Systems Director Management Console: Introduction and Overview9. The final page (Figure 12-14) shows the summary of all the configuration inp

Strona 276 - Network reconfiguration

Chapter 12. High availability and redundancy 321After the configuration completes, you can use the floating IP address to connect to the Systems Dir

Strona 277

322 IBM Systems Director Management Console: Introduction and Overview12.5 Active/Passive High Availability: UpdatesFor the initial release of the S

Strona 278 - Changing network settings

Chapter 12. High availability and redundancy 323The Director data is at a Snapshot level that is equivalent to when you started the upgrade. Events

Strona 279 - 9.3 Backup and restore

Chapter 1. Overview 9Table 1-2 POWER6 support by SDMCTable 1-3 POWER7 support by SDMCPOWER6 models Machine types SDMC595 9119-FHA HW APP Only575

Strona 280

324 IBM Systems Director Management Console: Introduction and Overview

Strona 281

© Copyright IBM Corp. 2011. All rights reserved. 325Chapter 13. Advanced System Management InterfaceIn this chapter, we describe how to log in to the

Strona 282

326 IBM Systems Director Management Console: Introduction and Overview13.1 Connecting to ASMI using the SDMCTo connect to the ASMI using the SDMC, p

Strona 283

Chapter 13. Advanced System Management Interface 3273. A page opens that has a drop-down menu for the service processor to which you want to connect

Strona 284

328 IBM Systems Director Management Console: Introduction and Overview4. A new browser page opens with the login page of the ASMI (Figure 13-3).Figur

Strona 285

Chapter 13. Advanced System Management Interface 32913.2 Connecting to ASMI using the CLITo connect to the ASMI using the SDMC command-line interfa

Strona 286

330 IBM Systems Director Management Console: Introduction and OverviewSystem Dump Initiates a system dump.Service Processor Dump Initiates a service

Strona 287

Chapter 13. Advanced System Management Interface 331Memory Serial Presence Detect DataShows manufactures data of detected memory modules.Firmware Ma

Strona 288 - KVM backup procedure

332 IBM Systems Director Management Console: Introduction and OverviewSelective Memory MirroringThis function is not available when your system is co

Strona 289 - Restoring on KVM

Chapter 13. Advanced System Management Interface 333򐂰 Network ServicesNetwork Configuration Displays and modifies the network configuration of the s

Strona 290 - 9.4 Problem determination

10 IBM Systems Director Management Console: Introduction and Overview1.5 TerminologyBased on the integration into IBM Systems Director, a common ter

Strona 291

334 IBM Systems Director Management Console: Introduction and Overview򐂰 Login ProfileChange Password Lets you change the general user, administrator,

Strona 292 - Trace logs in GUI

© Copyright IBM Corp. 2011. All rights reserved. 335Chapter 14. Service and supportThis chapter provides information about the service and support fea

Strona 293

336 IBM Systems Director Management Console: Introduction and Overview14.1 IntroductionService and Support Manager (SSM) is part of IBM Systems Dire

Strona 294

Chapter 14. Service and support 33714.2 Setup wizardTo set up the Service and Support Manager to report serviceable problems to IBM, you have to ru

Strona 295 - 9.4.4 Using pedbg

338 IBM Systems Director Management Console: Introduction and OverviewPerform the following steps:1. Click the Service and Support Manager Getting St

Strona 296 - 9.4.5 Using pesh

Chapter 14. Service and support 3392. On the next page, enter your company’s contact data (Figure 14-3).Figure 14-3 Company contact page

Strona 297 - 9.5 SDMC appliance update

340 IBM Systems Director Management Console: Introduction and Overview3. The fields marked by an asterisk are mandatory and must be completed before

Strona 298

Chapter 14. Service and support 3415. In the Connection page, you have to specify how the SDMC can connect to IBM, either through a direct Internet

Strona 299

342 IBM Systems Director Management Console: Introduction and Overview6. When you click Next, the Authorize IBM IDs page opens (Figure 14-6).Figure 1

Strona 300

Chapter 14. Service and support 3437. When you click Next, the Summary page opens (Figure 14-7).Figure 14-7 Summary page8. You can always go back

Strona 301 - Command-line interface

Chapter 1. Overview 11The command-line interface has been mostly kept the same. On the SDMC, most of the commands are just preceded by smcli. This n

Strona 302

344 IBM Systems Director Management Console: Introduction and OverviewThe tasks related to the Call Home feature are available on the context menu of

Strona 303

Chapter 14. Service and support 345Support FilesYou can use this task to collect the support files for the monitored system. The support files can b

Strona 304

346 IBM Systems Director Management Console: Introduction and Overview14.4 Serviceable event processingThe Service and Support Manager automatically

Strona 305

Chapter 14. Service and support 34714.4.2 Persistent storage and management of serviceable event dataService and Support Manager persists all the i

Strona 306

348 IBM Systems Director Management Console: Introduction and Overview14.4.5 User actionsYou can see a problems dashboard on top of the web interfac

Strona 307

Chapter 14. Service and support 349This page shows all the active problems reported for all discovered systems. Click any of the problems and you sh

Strona 308

350 IBM Systems Director Management Console: Introduction and OverviewThe General tab provides information from the Director Status Set of the event.

Strona 309

Chapter 14. Service and support 351You can also close a serviceable event by selecting Request Closure of a given service request, which causes the

Strona 310

352 IBM Systems Director Management Console: Introduction and OverviewSystem wide support files viewThe system wide support files view can be reached

Strona 311

Chapter 14. Service and support 353After you click the link, the Manage Support Files system wide view opens (Figure 14-14).Figure 14-14 Manage Su

Strona 312

12 IBM Systems Director Management Console: Introduction and Overview1.6.3 Additional functionsThe SDMC comes with the IBM Systems Director base man

Strona 313

354 IBM Systems Director Management Console: Introduction and OverviewMonitored system support files viewThe monitored system support files view can

Strona 314

Chapter 14. Service and support 355Serviceable problem support files viewThe serviceable problem support files view can be reached over an active se

Strona 315 - Schedule operations

356 IBM Systems Director Management Console: Introduction and Overview򐂰 Submit support files to IBM by clicking the Submit to IBM... button, or by us

Strona 316 - Virtual Servers

Chapter 14. Service and support 357Figure 14-17 Collect Support Files pageYou can only get support files from one system at a time. Specify the ty

Strona 317

358 IBM Systems Director Management Console: Introduction and OverviewSystem dump A system dump is a dump of the hardware and server firmware content

Strona 318 - 11.1.1 Schedule tab

Chapter 14. Service and support 359There are two other tasks that can be used to remove support files򐂰 The Service and Support Manager Support File

Strona 319 - 11.1.3 Options

360 IBM Systems Director Management Console: Introduction and OverviewProperties of support filesOn the General tab of the properties page of a suppo

Strona 320 - 11.1.4 Creating the job

Chapter 14. Service and support 361򐂰 You can see the location where the support files are saved locally.򐂰 You can see the free space left for the su

Strona 321

362 IBM Systems Director Management Console: Introduction and Overview14.6 Service and Support Manager command-line interfaceThe Service and Support

Strona 322 - Figure 11-7 Log of the job

Chapter 14. Service and support 36314.7 Service and Support Manager tasksThe Service and Support Manger (SSM) defines a number of tasks (scheduled

Strona 323 - 11.3 Automation Manager

Chapter 1. Overview 131.6.7 SDMC considerationsHere is the list of limitations for SDMC when compared with the HMC:򐂰 The system plans feature is no

Strona 324

364 IBM Systems Director Management Console: Introduction and Overview򐂰 Collect Performance DataThis task runs on a daily basis. It is performed for

Strona 325 - High availability and

Chapter 14. Service and support 36514.9 Guided RepairYou can perform Guided Repair procedures from the context menu of a managed system. Right-clic

Strona 326

366 IBM Systems Director Management Console: Introduction and OverviewProblem Repair You can execute a repair from the Problem Information page, whic

Strona 327

© Copyright IBM Corp. 2011. All rights reserved. 367Appendix A. Command-line referenceIn this appendix, we list the IBM Systems Director Management Co

Strona 328

368 IBM Systems Director Management Console: Introduction and OverviewIBM Power Systems management commandsThis section lists the Power Systems manag

Strona 329 - Post-Failover

Appendix A. Command-line reference 369Table A-3 shows information about the mk5250 command.Table A-3 mk5250 commandTable A-4 shows information abo

Strona 330

370 IBM Systems Director Management Console: Introduction and OverviewIBM Systems Director application commandsThis section lists the IBM Systems Dir

Strona 331

Appendix A. Command-line reference 371Event commandsThis section lists the commands for event handling. To see the options of the commands in the ev

Strona 332

372 IBM Systems Director Management Console: Introduction and OverviewTable A-10 shows information about the listeventactions command.Table A-10 li

Strona 333

Appendix A. Command-line reference 373Table A-13 shows information about the listfilters command.Table A-13 listfilters commandScheduler commandsI

Strona 334 - 12.3.1 Network requirements

© Copyright International Business Machines Corporation 2011. All rights reserved.Note to U.S. Government Users Restricted Rights -- Use, duplication

Strona 335 - Network status IP address

14 IBM Systems Director Management Console: Introduction and Overview

Strona 336

374 IBM Systems Director Management Console: Introduction and OverviewTable A-16 shows information about the getjobstatus command.Table A-16 getjob

Strona 337 - 12.3.2 DHCP considerations

Appendix A. Command-line reference 375SSM commandsIn this section, we list the commands for the Service and Support Manager (SSM).Table A-20 shows i

Strona 338 - Shared DHCP configuration

376 IBM Systems Director Management Console: Introduction and OverviewTable A-22 shows information about the cpsptfile command.Table A-22 cpsptfile

Strona 339

Appendix A. Command-line reference 377Table A-23 shows information about the lssptfile command.Table A-23 lssptfile commandCommand lssptfileDefini

Strona 340 - Figure 12-8 Welcome page

378 IBM Systems Director Management Console: Introduction and OverviewTable A-24 shows information about the lssvcproblem command.Table A-24 lssvcp

Strona 341

Appendix A. Command-line reference 379Table A-26 shows information about the ssmimport command.Table A-26 ssmimport commandExample This example il

Strona 342

380 IBM Systems Director Management Console: Introduction and OverviewTable A-27 shows information about the submitsptfile command.Table A-27 submi

Strona 343

Appendix A. Command-line reference 381Syntax smcli configureHA--secondary-node secNode--password thePassword--primary-rep-addr primRepAddr--secondar

Strona 344

382 IBM Systems Director Management Console: Introduction and OverviewTable A-29 shows information about the failover command.Table A-29 failover c

Strona 345 - Click Next

Appendix A. Command-line reference 383Table A-30 shows information about the removeHA command.Table A-30 removeHA commandUser commandsIn this sect

Strona 346 - Figure 12-14 Summary page

© Copyright IBM Corp. 2011. All rights reserved. 15Chapter 2. InstallationIn this chapter, we describe the installation of the IBM Systems Director Ma

Strona 347 - Additional command-line tools

384 IBM Systems Director Management Console: Introduction and OverviewTable A-32 shows information about the rmuser command.Table A-32 rmuser comma

Strona 348

Appendix A. Command-line reference 385Other commandsIn this section, we list commands not listed in the previous sections.Table A-33 shows informati

Strona 349

386 IBM Systems Director Management Console: Introduction and OverviewTable A-35 shows information about the licensestatus command.Table A-35 licen

Strona 350

Appendix A. Command-line reference 387Table A-39 shows information about the startdiscovery command.Table A-39 startdiscovery commandTable A-40 sh

Strona 351 - Management Interface

388 IBM Systems Director Management Console: Introduction and Overview

Strona 352

© Copyright IBM Corp. 2011. All rights reserved. 389Appendix B. IBM Systems Director base functionsIn this appendix, we discuss the IBM Systems Direct

Strona 353

390 IBM Systems Director Management Console: Introduction and OverviewBase functionsBase functions (plug-ins) in IBM Systems Director provide core fu

Strona 354 - Figure 13-3 ASMI login

Appendix B. IBM Systems Director base functions 391Configuration ManagerThe Configuration Manager is used to integrate new hardware into your enviro

Strona 355 - 13.3 Using ASMI

392 IBM Systems Director Management Console: Introduction and OverviewIBM Power Systems managementIBM Power Systems management provides life cycle ma

Strona 356

© Copyright IBM Corp. 2011. All rights reserved. 393Appendix C. IBM Systems Director Management Console distribution detailsIn this appendix, we give

Strona 357

16 IBM Systems Director Management Console: Introduction and Overview2.1 PrerequisitesThis section lists the requirements and pre-requisites for the

Strona 358

394 IBM Systems Director Management Console: Introduction and OverviewIBM Systems Director Management Console virtual disk imagesTable C-1 shows the

Strona 359

© Copyright IBM Corp. 2011. All rights reserved. 395AME Active Memory ExpansionAMM Advanced Management ModuleAMS Active Memory SharingASM Advanced Sy

Strona 360

396 IBM Systems Director Management Console: Introduction and OverviewSMS Systems Management ServicesSPCN System Power Control NetworkSSH Secure Shel

Strona 361 - Service and support

© Copyright IBM Corp. 2011. All rights reserved. 397Related publicationsThe publications listed in this section are considered particularly suitable f

Strona 362 - 14.1 Introduction

398 IBM Systems Director Management Console: Introduction and Overview򐂰 IBM Fix Centralhttp://www.ibm.com/support/fixcentral/򐂰 IBM Systems Director 6

Strona 363 - 14.2 Setup wizard

© Copyright IBM Corp. 2011. All rights reserved. 399IndexNumerics7042-CR6 16–17Aaccesssys command 82activate Virtual Server 152Active and Sched

Strona 364 - Perform the following steps:

400 IBM Systems Director Management Console: Introduction and Overviewfailover 321impdata 68, 282lsbundle 278lsldap 228lsled 59lsnetcfg 2

Strona 365

Index 401configuration 246First Failure Data Capture (FFDC) 364Flexible Service Processor (FSP) 308failover 365floating IP address 303, 30

Strona 366

402 IBM Systems Director Management Console: Introduction and Overviewstates 10LPAR See logical partitionlsbundle command 278lsldap command 228

Strona 367 - Figure 14-5 Connection page

Index 403rediscover command 83redundancy 12, 299–301relocation 10Remote Access Manager 391Remote Command Execution 276Remote Monitoring an

Strona 368

Chapter 2. Installation 17The supported host operating systems and hypervisors are:򐂰 Red Hat Enterprise Linux (RHEL) 5.5 with KVM (kvm-83-164.el5) o

Strona 369 - 14.3 Call Home

404 IBM Systems Director Management Console: Introduction and Overviewsmhastatus command 320–321SMManager role 10, 199, 205smmgr group 202smmon

Strona 370

Index 405Xx86 hardware 16–17

Strona 371

406 IBM Systems Director Management Console: Introduction and Overview

Strona 372

(0.5” spine)0.475”<->0.875”250 <-> 459 pagesIBM Systems Director Management Console: Introduction and Overview

Strona 375

®SG24-7860-00 ISBN 0738435449INTERNATIONAL TECHNICALSUPPORTORGANIZATIONBUILDING TECHNICALINFORMATION BASED ONPRACTICAL EXPERIENCE IBM Redbooks are dev

Strona 376

18 IBM Systems Director Management Console: Introduction and Overview2.2.1 Hardware installationFor the hardware appliance, you need at least one ne

Strona 377 - 14.5.1 Support Files view

Chapter 2. Installation 192. After DVD1 is copied, the following prompt appears:Press Enter to shutdown the system. After the system is powered off,

Strona 378 - Tasks (Figure 14-13)

20 IBM Systems Director Management Console: Introduction and Overview򐂰 A graphical interface on the VMWare Virtual Infrastructure ClientTo use the CL

Strona 379 - (Figure 14-14)

Chapter 2. Installation 212. Select File  Deploy OVF Template, as shown in Figure 2-2.Figure 2-2 Deploy OVF Template from vSphere Client

Strona 380

22 IBM Systems Director Management Console: Introduction and Overview3. Select the Deploy from file radio button and click the Browse button. Navigat

Strona 381

Chapter 2. Installation 234. Continue through the pages until you reach the Ready to Complete page. Review the deployment settings and click Finish

Strona 382

© Copyright IBM Corp. 2011. All rights reserved. iiiContentsFigures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 383

24 IBM Systems Director Management Console: Introduction and Overview2. Because all files and images needed are contained within the OVA, you can sim

Strona 384 - Deleting support files

Chapter 2. Installation 25This command extract the disk images (dvmdisk1.img, dvmdisk2.img, dvmdisk3.img,...dvmdisk7.img).4. Create the domain XML f

Strona 385

26 IBM Systems Director Management Console: Introduction and OverviewSee the sample domain.xml file in Example 2-2. The tags that might have to be cu

Strona 386 - Properties of support files

Chapter 2. Installation 27 </disk> <disk type="file" device="disk"> <source file="/vdisk1/vm1/dvm

Strona 387 - Dump settings

28 IBM Systems Director Management Console: Introduction and Overview5. Define VM by running the following command:virsh define <domain>.xml6.

Strona 388

Chapter 2. Installation 29– pt_br: Brazilian Portuguese– zh_CN: Simplified Chinese– zh_TW: Traditional Chinese2. Accept the IBM Software License Agr

Strona 389

30 IBM Systems Director Management Console: Introduction and Overview3. After accepting the license agreement, the Welcome page of the setup wizard o

Strona 390

Chapter 2. Installation 314. Enter the date, time, and time zone for your location (Figure 2-8).Figure 2-8 Date and Time page

Strona 391 - 14.9 Guided Repair

32 IBM Systems Director Management Console: Introduction and Overview5. The next four pages request the passwords for the sysadmin, root, and pe user

Strona 392 - 14.9.1 Differences from HMC

Chapter 2. Installation 33square brackets ([ ]), backslash (\), colon (:), quotation mark ("), semicolon (;), and apostrophe ('). – Passwo

Strona 393 - Command-line reference

iv IBM Systems Director Management Console: Introduction and Overview2.3.2 VMware installation . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 394

34 IBM Systems Director Management Console: Introduction and Overview8. The last page to complete is the Agent Manager configuration page (Figure 2-1

Strona 395

Chapter 2. Installation 359. After completing the last page and clicking Next, the Summary page opens (Figure 2-12). You can always go back from her

Strona 396

36 IBM Systems Director Management Console: Introduction and Overview10.If all went well, you see the System Setup Processing page; a status of Succe

Strona 397 - Event commands

Chapter 2. Installation 3711.After clicking Close, the SDMC boots and a startup page opens (Figure 2-14).Figure 2-14 Console starting page

Strona 398

38 IBM Systems Director Management Console: Introduction and OverviewThe startup takes up to five minutes. When the startup is finished, the Systems

Strona 399 - Scheduler commands

Chapter 2. Installation 392.5.1 SDMC hardware applianceFor the SDMC hardware appliance, the customer needs to order the 7042-CR6 machine type with

Strona 400

40 IBM Systems Director Management Console: Introduction and Overview

Strona 401 - SSM commands

© Copyright IBM Corp. 2011. All rights reserved. 41Chapter 3. Basic operationThis chapter provides an overview of features and tasks provided by IBM S

Strona 402

42 IBM Systems Director Management Console: Introduction and Overview3.1 Features overviewThe SDMC is now available as part of the IBM Systems Direc

Strona 403

Chapter 3. Basic operation 43Edit host This task displays the properties of the server. The properties contain information about the processors, mem

Strona 404

Contents v5.1.1 System discovery functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 765.1.2 Discovery of POWER processor-bas

Strona 405

44 IBM Systems Director Management Console: Introduction and OverviewCollect utilization dataYou can set the SDMC to collect the resource utilization

Strona 406 - High availability commands

Chapter 3. Basic operation 45Suspend and resume Virtual ServersYou can suspend Virtual Servers to store its state on a Storage Area Network (SAN). Y

Strona 407

46 IBM Systems Director Management Console: Introduction and OverviewRebuild Power Unit Use this task to rebuild the Power Unit information in the SD

Strona 408

Chapter 3. Basic operation 47Security and user managementYou can create users and roles. You can assign permissions to roles and assign the roles to

Strona 409 - User commands

48 IBM Systems Director Management Console: Introduction and OverviewSupport file managementSSM provides the following capabilities for managing supp

Strona 410

Chapter 3. Basic operation 493.2 Using the web interfaceSDMC provides a web interface similar to the HMC. Power on the SDMC appliance and you shoul

Strona 411 - Other commands

50 IBM Systems Director Management Console: Introduction and OverviewEnter the user ID and password that corresponds to an authorized SDMC user and c

Strona 412

Chapter 3. Basic operation 51There could be other non-Power Systems that are discovered and managed by SDMC. You can see these systems in the Naviga

Strona 413

52 IBM Systems Director Management Console: Introduction and OverviewYou can open multiple views or pages and have them open as tabs at the same time

Strona 414

Chapter 3. Basic operation 53Figure 3-3 shows a snapshot of the layout of the management tasks on the context menu of the server.Figure 3-3 Contex

Strona 415 - IBM Systems Director base

vi IBM Systems Director Management Console: Introduction and Overview8.2 Virtual Server activation . . . . . . . . . . . . . . . . . . . . . . . .

Strona 416 - Base functions

54 IBM Systems Director Management Console: Introduction and OverviewFigure 3-4 shows the other tasks that are available in the context menu of the s

Strona 417

Chapter 3. Basic operation 55Figure 3-5 shows a snapshot of the layout of the management tasks available on the context menu of the Virtual Server.F

Strona 418

56 IBM Systems Director Management Console: Introduction and OverviewTable viewThe table view displays a list of resources along with their informati

Strona 419

Chapter 3. Basic operation 57Properties viewThe properties view displays a list of properties and other detailed information related to the selected

Strona 420

58 IBM Systems Director Management Console: Introduction and OverviewTopology viewThe topology view displays the relationship among your resources. S

Strona 421 - Abbreviations and acronyms

Chapter 3. Basic operation 593.3 Command-line interfaceThe IBM Systems Director provides the systems management command-line interface, referred to

Strona 422

60 IBM Systems Director Management Console: Introduction and Overview

Strona 423 - Related publications

© Copyright IBM Corp. 2011. All rights reserved. 61Chapter 4. Making the transition to the IBM Systems Director Management ConsoleThis chapter describ

Strona 424 - Help from IBM

62 IBM Systems Director Management Console: Introduction and Overview4.1 ConceptsTransition is a new feature that is available to transition systems

Strona 425 - Numerics

Chapter 4. Making the transition to the IBM Systems Director Management Console 634.2.1 What is transitionedWhen you transition managed systems fro

Strona 426

Contents vii11.1 Scheduling operations for managed systems and Virtual Servers . . . . 29011.1.1 Schedule tab . . . . . . . . . . . . . . . . . .

Strona 427

64 IBM Systems Director Management Console: Introduction and Overview򐂰 Creates default profiles based on Virtual Server current configuration read fr

Strona 428

Chapter 4. Making the transition to the IBM Systems Director Management Console 654.3 HMC to SDMC transitionThis section describes how you can tran

Strona 429

66 IBM Systems Director Management Console: Introduction and OverviewPerform the following steps to perform an online transition:1. Launch the transi

Strona 430

Chapter 4. Making the transition to the IBM Systems Director Management Console 674. You should now see a list of managed systems (Figure 4-2) that

Strona 431

68 IBM Systems Director Management Console: Introduction and OverviewAfter successful authentication, the Access state of the managed system changes

Strona 432

Chapter 4. Making the transition to the IBM Systems Director Management Console 69All serviceable events must be closed before you can execute this

Strona 433

70 IBM Systems Director Management Console: Introduction and Overview5. Browse to and select the exported configuration data file from step 1 (Figure

Strona 434

Chapter 4. Making the transition to the IBM Systems Director Management Console 714.3.6 Offline transition using the command-line interfacePerform

Strona 435

72 IBM Systems Director Management Console: Introduction and OverviewThe flow chart in Figure 4-4 shows a snapshot of the complete transition process

Strona 436

Chapter 4. Making the transition to the IBM Systems Director Management Console 734.4.1 SDMC as the DHCP serverPerform the following steps to perfo

Komentarze do niniejszej Instrukcji

Brak uwag

MSB Technology Equipo musical manuales de usuario

Empezando en D

Haga clic en el alfabeto a continuación para desplazarse a la lista completa de modelos que comienzan con esa letra

Modelos Tipo de documento
DAC II
Manual de usuario   MSB Technology DAC II User's Manual, 7 paginas
Diamond DAC IV
Especificaciones   MSB Technology Diamond DAC IV Specifications, 15 paginas
Especificaciones   MSB Technology Diamond DAC IV Specifications [en] , 20 paginas
Manual de usuario   signature dac iv plus, 2 paginas